PULSAR-2.1Ultrasonic pulse velocity test instrument

  pcs.
ADD TO FAVORITES REMOVE FROM FAVORITES
  • Electronic unit, casing
  • Transducers (depend on the version):
    • Version 1 - pulse echo (single side access) transducer
    • Version 2 - 2 x through transmission transducers
    • Version 3 - pulse echo (single side access) and 2 x through transmission transducers
  • 2 x 1,5 m cable set
  • 3m cable (version 2, version 3)
  • Calibration prism
  • USB charger (1А)
  • USB card with PC software
  • USB cable
  • Operating instructions
  • Bag
  • Verification or calibration certificate (on request)

Hydro-insulated transducer (single side access)

Hydro-insulated transducer (single side access)

ADD TO FAVORITES REMOVE FROM FAVORITES

Conical nozzles for through transmittion transducers (dry point contact), 2 pcs

Conical nozzles for through transmittion transducers (dry point contact), 2 pcs

ADD TO FAVORITES REMOVE FROM FAVORITES

Hydro-insulated through transmittion transducers, 2 pcs

Hydro-insulated through transmittion transducers, 2 pcs

ADD TO FAVORITES REMOVE FROM FAVORITES

Hydro-insulated cable set, 1.5 m (2 pcs)

Hydro-insulated cable set, 1.5 m (2 pcs)

ADD TO FAVORITES REMOVE FROM FAVORITES

Plastic case for PULSAR-2.1 / 2.2

Plastic case for PULSAR-2.1 / 2.2

ADD TO FAVORITES REMOVE FROM FAVORITES
  • Measurement of transit time and pulse velocity at superficial and through sonic testing
  • Testing of strength, uniformity and type of concrete, brick and other materials
  • Detection of voids, cracks and other anomalies, measurement of perpendicular surface crack depth during technological control and inspection of objects
  • Estimation of concrete maturity degree at solid-cast concreting
  • Determining of density and elasticity modulus of materials, sonic index of abrasives
  • Estimation of honeycombing, cracking and anisotropy of materials
  • The results are not critical to the pressing force of transducers (patent)
  • Due to the increased energizing pulse and enhanced correlation "signal – noise", the instrument is efficient at large bases of sonic testing
  • Universal transducers with automated combination of the transmitter voltage and the receiver gain, ensures an optimum received signal level, guaranteeing accurate and stable measurements
  • Pulse echo (single side access) transducer with fixed base:
    – handle made from superlight and warm material enables to test objects with poor strength at minimum pulse velocity from 1200 m/sec
    – 120 mm base which is necessary to graduate the instrument using sample cubes of 100 mm side
    – exponential durable transducers with dry point contact for rough surfaces
  • Transducer type depends on the version
  • Pulse echo and through transmission waterproof transducers with FISHER connectors (option) to examine the hydrotechnical objects under water
  • High-resolution 3.5-inch color TFT display
  • Built-in lithium accumulator of a large capacity and power unit for continuous operation and restoration
  • Automatic stabilization of the first arrival of the ultrasonic pulse mark position
  • Measuring time and speed of ultrasonic pulse during pulse echo and through transmission testing
  • Result acquisition after an automatic series of 2 ... 10 measurements
  • Testing strength of concrete and brick and strength quality of concrete
  • Measurement of perpendicular surface crack depth using «Russian» and «English» methods
  • Calculation of density, modulus of elasticity and sonic index of materials
  • Universal and individual concrete correlations with user-specified materials
  • Up to 1000 testing protocols including data and type of object
  • Russian/English menu availble
  • USB interface and special service software
Range of time readings, µs  10...20000
Range of time measurement, µs  10...1000
Resolution capability, µs  0,05
Limits of permissible general absolute error of time measurement, µs ±(0,01t + 0,1)
Range of speed measurement, m/sec 1000....10000
Limits of permissible general absolute error of speed measurement, m/sec ±(0,01v + 10)
Limits of permissible supplementary absolute error of speed and time measurement under deviation of operation temperature for each 10 ºС within operating range, in fractions of the general error, maximum 0,5
Optimized energizing pulse, V 450 /  600*
Bandwidth, KHz 60±10 / 20...200*
Memory capacity, Gb  до 4
Display resolution  320х240
Electronic unit dimensions, less than, mm  205х115х35
Electronic unit / pulse echo transducer weight, kg 0,44 / 0,58

* - optional

  • Data download to PC
  • Data saving, recording and processing
  • Impact graphs viewing
  • Data transfer to Excel spreadsheet, textual documents and other applications
  • Quick calibration factors determining with the PC software ApproximPulsar.exe

Collect your order in the cart,